{"product_id":"3-loop-hydronic-heating-manifold-with-24v-electric-thermal-actuators","title":"3-Loop Hydronic Heating Manifold with 24V Electric Thermal Actuators","description":"\u003cp\u003eThe WiseWater 3-loop hydronic heating manifold is a complete manifold assembly for radiant floor heating and other hydronic heating systems. It includes three 24V normally closed electric thermal actuators, 1\/2\" PEX adapters, flowmeters, temperature gauges, an automatic air vent, and drain components.\u003c\/p\u003e\n\u003cp\u003eThe manifold features \u003cstrong\u003e1\" FPT supply and return connections\u003c\/strong\u003e and three individual \u003cstrong\u003e1\/2\" heating loop outlets\u003c\/strong\u003e. Each loop includes a flowmeter for monitoring and adjusting flow, while the electric thermal actuator can be connected to a compatible thermostat or zone control system for individual circuit control.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3-loop\u003c\/strong\u003e hydronic heating manifold\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\" FPT\u003c\/strong\u003e supply and return connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\/2\" PEX adapters\u003c\/strong\u003e included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3 × 24V, 2-wire normally closed\u003c\/strong\u003e electric thermal actuators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eListed flow: \u003cstrong\u003eup to 1.4 GPM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlowmeters for individual loop flow monitoring and adjustment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual-scale temperature gauges for supply and return temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic air vent and drain components with outlet caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStainless steel manifold construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e24V Electric Thermal Actuators\u003c\/h3\u003e\n\u003cp\u003eEach heating loop is equipped with a \u003cstrong\u003e24V, 2-wire, normally closed (NC)\u003c\/strong\u003e electric thermal actuator. When connected to a compatible thermostat or zone-control system, the actuators can control the opening and closing of the individual heating circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThermostat and zone-control equipment are not included.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eFlow \u0026amp; Temperature Monitoring\u003c\/h3\u003e\n\u003cp\u003eEach loop includes a flowmeter\/valve assembly for visual flow monitoring and adjustment. Dual-scale temperature gauges provide a convenient way to monitor supply and return temperatures at the manifold.\u003c\/p\u003e\n\u003ch3\u003eAir Vent \u0026amp; Drain\u003c\/h3\u003e\n\u003cp\u003eThe integrated automatic air vent helps remove accumulated air from the manifold. The drain components can be used for system filling, draining, and routine servicing.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eSuitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHydronic radiant floor heating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eZoned hydronic heating systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable radiator circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResidential and other hydronic heating applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWiseWater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3 Loop \u0026amp; 3 ETA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Loops\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply \/ Return\u003c\/td\u003e\n\u003ctd\u003e1\" FPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Connections\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePEX Adapters\u003c\/td\u003e\n\u003ctd\u003e1\/2\" included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed Flow\u003c\/td\u003e\n\u003ctd\u003eUp to 1.4 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuators\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator Wiring\u003c\/td\u003e\n\u003ctd\u003e2-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator Type\u003c\/td\u003e\n\u003ctd\u003eNormally Closed (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlowmeters\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Gauges\u003c\/td\u003e\n\u003ctd\u003eDual-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Vent\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManifold Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.39\" × 3.54\" × 13.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 × 3-loop hydronic heating manifold\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e3 × 24V normally closed electric thermal actuators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1\/2\" PEX adapters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlowmeter\/valve assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual-scale temperature gauges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic air vent\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrain components and outlet caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eVerify that the \u003cstrong\u003e1\" FPT supply\/return connections, 1\/2\" PEX adapters, 24V actuator specifications, and system flow requirements\u003c\/strong\u003e are compatible with your heating system before installation.\u003c\/p\u003e\n\u003cp\u003eActual system flow and heating performance depend on the complete system design, including pump capacity, piping configuration, loop length, water temperature, and other operating conditions.\u003c\/p\u003e","brand":"Alfa Heating Supply","offers":[{"title":"Default Title","offer_id":47977764061355,"sku":"WW-3RM-3ETA","price":249.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1775\/3277\/files\/71e1HL5vymL._AC_SL1500.jpg?v=1790754670","url":"https:\/\/alfaheating.com\/products\/3-loop-hydronic-heating-manifold-with-24v-electric-thermal-actuators","provider":"Alfa Heating Supply","version":"1.0","type":"link"}